INSTALLATION INSTRUCTIONS FOR X10 IN-WALL APPLIANCE MODULE AW12
Switch off appropriate mains fuse and master switch!
Important: 230V - 50Hz - 16A max.
This module can be activated by using a toggle switch or a push button or using X10 PLC signals. It can be operated using the following X10 signals: "Address On", "Address
Off and "All Lights On/All Lights Off/All Units Off" if this option is programmed. The unit will accept either a momentary acting key or a standard wall switch with latching
action. All key closures must be to Live. If a momentary key is used, the relay changes state each time the key is pressed, as long as the key press lasts for less than 1.75
seconds.
If a standard wall switch with latching action is used, it is assumed that the key press will last for more than 1.75 seconds. In this case the relay changes state on both the
closure and opening. This type of response will allow the unit to also perform 2-way control if 2 changeover latching switches are connected in series as would be the case
with 2 way switching.
Installation
To install the AW12, neutral and phase are required at the installation point
- Switch off appropriate mains fuse and master switch!
- Take the wall switch out of the wall box.
- Disconnect all wires f rom the switch
- Pull an additional Neutral wire if it is missing
- Connect the live and neutral to the terminal wires of the AW12 as described in the drawing.
- Connect the wires from the In-Wall module to the switch.
- Connect the phase to the switch
- Re-install the wall switch on the wall box
- Switch on mains fuse and master switch
Programming
Default Setting:
The default factory address is A1. If the address and "All lights on/All lights off /All Units Off" option
settings are not known, the default address of A1 can be set by applying power to the unit and sending
the address P16 to the unit twice (using any X10 controller - i.e.: TM13 + RF remote control). This can
either be just the address “P16” or “P16 On” or “P16 Off”. The messages must be sent within 30
seconds of applying power to the unit .
Setting the default address automatically cancels the options to respond to either "All Lights On", "All
Lights Off" or "All Units Off".
Setting the Address and "All Lights On/All Lights Off/All Units Off" Option:
To change the address and set up the "All Lights On/All Lights Off/All Units Off " option the unit must first be put into Program Mode. To enter Program Mode either send
Address On and Address Off in a quick sequence or press the external key quickly . After the relay changes state 5 times, with no more than 1.75 seconds between each
change of state, the unit will enter Program Mode and the relay will stop responding to indicate that it has entered the Program Mode. Once in Program Mode the new
address can be set by sending an Address or Address On or Address Off message on the new address code twice (using any X10 controller). If you want to change the
code again, just send the revised code twice as before .
To set the unit to respond to "All Lights On" and/or "All Lights Off" and/or "All Units Off" just send these messages twice on the new address code (using any X10 controller).
Please note: The "All Lights On/All Lights Off /All Units Off " option can be disabled by setting a new address or by returning to the Default Setting as above.
To return to Run Mode: either send "Address On", "Address Off" or press the key quickly (no more than 1.75 seconds between key press). After 5 key presses or "On/Off"
message, the relay will start to respond, indicating that the unit is back in Run Mode. If no action is taken, the unit will automatically return to Run Mode after 60 seconds.
Important notice: After the installation of the X10 controllers, all receiver modules have first to be checked for correct function and address!
Technical Data: Supply voltage: 230 V +10% -15% 50 Hz, Supply current: <20 mA capacitive. Making capacity: 2000 W (incandescent lamp), 3 A (motors), 16 A (resistive
loads).
INSTALLATION INSTRUCTIONS FOR X10 IN-WALL DIMMER MODULE LW12
Switch off appropriate mains fuse and master switch!
Important: 230V - 50Hz 60 to 250W - Works with incandescent lamp and dimmable electronic low voltage transformer.
Not suitable for Low Energy Fluorescent lamps.
Must only be used in circuits protected by a Fuse or Circuit Breaker rated at 16A or less.
The module is protected against overload, but may be damaged if the SL Output is shorted directly to Neutral.
The LW12 is a 2-wire X10 compatible dimmer for controlling Incandescent Lamps and Dimmable Electronic Low Voltage Transformers down to 60W. This module can be
activated using a momentary action Key or using X10 PLC signals. It can be operated using the following X10 signals: "Address On", "Address Off , “Address Bright”,
“Address Dim” and "All Lights On/All Lights Off/All Units Off" if these last 3 options are programmed. This unit will also respond to “Extended” X10 messages-Scenes. The
unit’s Address, Response Options, Scene Responses, Output Memory Level and On/Off Status are all stored in permanent memory and are preserved through a loss of
power. The output status is reinstated after power returns. The unit will accept a momentary action key. All key closures must be to live and to the same phase that the unit is
powered.
Installation
To install the LW12, only the phase is required at the installation point
- Switch off appropriate mains fuse and master switch!
- Take the wall switch (momentary action switch) out of the wall box
- Disconnect all wires from the switch
- Connect the live to the L terminal of the LW12
- Connect the momentary action switch between the live and the K terminal of the LW12
- Connect the load to SL terminal
- Re-fix the wall switch on the wall box
- Switch on mains fuse and master switch
Programming
Default Setting:
The default factory address is A1. If the address and "All lights On / All lights Off / All Units Off" option settings aren’t known, the default address of A1 can be set by applying
power to the unit and sending the address P16 to the unit twice (using any X10 controller - i.e.: TM13 + RF remote control). This can either be just the address “P16” or “P16
On” or “P16 Off”. The messages must be sent within 30 seconds of applying power to the unit. Setting the default address automatically cancels the options to respond to
either "All Lights On", "All Lights Off”, “All Units Off" or any scene command.
Setting the Address and "All Lights On/All Lights Off/All Units Off" Option
To change the address and set up the "All Lights On/All Lights Off/All Units Off” option the unit must first be put into Program Mode. To enter Program Mode either send
Address On and Address Off in quick succession or press the external key quickly. After 5 changes, with no more than 2 seconds between each change of state, the unit
will enter Program Mode and the unit will stop responding to indicate that it has entered the Program Mode.
Note: Because this is a dimmer with built in Fade-on and Fade-off it takes some seconds to visibly change the output on/off state. This can make it quite difficult to switch the
output on and off quickly and be able to see when the unit stops responding as it goes into program mode. To make it easier, it is recommended to first dim the unit somewhat
before starting the Program Mode sequence.
Once in Program Mode the new address can be set by sending an Address or Address On or Address Off message on the new address code twice (using any X10
controller). If you want to change the code again, just send the revised code twice as before.
To set the unit to respond to "All Lights On" and/or "All Lights Off" and/or "All Units Off" just send these messages twice on the new address code (using any X10 controller).
Please note: The "All Lights On/All Lights Off /All Units Off” option will be disabled by setting a new address or by returning to the Default Setting as above.
K
L
SL
Incandescent Lamp
Neutral
Live
Momentary action
key
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - Standard Switch or

www.bmb-home.com Rev: BMB-14.05.05 2 Way Switching Standard Switch or momentary switch NNLSLLamp NeutralLiveSwitchSwitchNNLSLLamp NeutralL

Page 2 - Troubleshooting

www.bmb-home.com Rev: BMB-14.05.05 To return to Run Mode: either send "Address On", "Address Off" or press the key qui

Page 3

www.bmb-home.com Rev: BMB-14.05.05 2 Way Switching Standard Switch or momentary switch NNLSLLamp NeutralLiveSwitchSwitchNNLSLLamp NeutralL

Page 4 - Problembehebung

www.bmb-home.com Rev: BMB-14.05.05 externe Taste. Nach fünf Wechseln, mit nicht mehr als zwei Sekunden zwischen jedem Stauswechsel, wird d

Page 5

www.bmb-home.com Rev: BMB-14.05.05 N N LSLLamp Nul (blauw) Fase 230V (bruin) Schakelaar Schakelaar Wisselschakeling Standaard- of Pu

Page 6 - Oplossen van Problemen

www.bmb-home.com Rev: BMB-14.05.05 Programmeren van het adres en de optionele functies All Lights On/All Lights Off/All Units Off: Om het

Page 7 - "Va et Vient"

www.bmb-home.com Rev: BMB-14.05.05 Interrupteur standard ou bouton poussoir "Va et Vient" NNLSLLampe NeutrePhaseInterrupteur ou

Page 8 - Problèmes de Fonctionnement

www.bmb-home.com Rev: BMB-14.05.05 Une fois en mode Programmation, programmez la nouvelle adresse en envoyant celle-ci 2 fois de suite à l